T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32

T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32 


A revolution in design, efficiency, connectivity and sustainability. Aquarea K Series is a ground breaking low-energy system for heating, cooling and domestic hot water production that delivers outstanding performance. Aquarea T-CAP is the range for retrofit and new builds, keeping rated capacity even at extremely cold ambient.

Now available in a larger All in One version, perfect for homes with high DHW demand. Despite the increased capacity, it maintains a compact footprint of just 599 x 602 mm—similar to a standard appliance.



• A+++ in heating at 35°C and A+ in DHW
• Stainless steel DHW tank with U-Vacua™ insulation panel
• 598 x 600 footprint
• Built-in magnetic water filter
• Rated capacity down to -15°C at 55 ºC water outlet
• Operating range down to -28°C
• Optional Wi-Fi adapter

Further comfort and peace of mind with Aquarea

Technische Daten

Alles anzeigen
T-CAP All in One 260l DHW tank K Series 1 phase - 3 phase · R32 Einphasig Dreiphasig
9.00 kW 16.00 kW
Kit 6kW electric heater KIT-AXC09K6E53
Heizleistung (A +7°C, W 35°C) kW 9,00 16,00
COP (A +7°C, W 35°C) 5,03 4,38
Heizleistung (A +7°C, W 55°C) kW 9,00 16,00
COP (A +7°C, W 55°C) 3,07 2,72
Heizleistung (A +2°C, W 35°C) kW 9,00 16,00
COP (A +2°C, W 35°C) 3,69 3,10
Heizleistung (A +2°C, W 55°C) kW 9,00 16,00
COP (A +2°C, W 55°C) 2,31 2,07
Heizleistung (A -7°C, W 35°C) kW 9,00 16,00
COP (A -7°C, W 35°C) 3,00 2,39
Heating capacity (A -7°C, W 55°C) kW 9,00 16,00
COP (A -7°C, W 55°C) 2,10 1,71
Kühlleistung (A 35°C, W 7°C) kW 8,80 13,40
EER (A 35°C, W 7°C) 3,11 2,64
Kühlleistung (A 35°C, W 18°C) kW 8,80 15,50
EER (A 35°C, W 18°C) 4,63 3,60
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,96 / 3,57 4,46 / 3,31
Mittleres Klima. Raumheizungs-Energieeffizienz (W 35°C / W 55°C) ηs % 195 / 140) 176 / 129)
Mittleres Klima. Raumheizungs-Energieeffizienzklasse (W 35°C / W 55°C) (1) A+++ to D A+++ / A++ A+++ / A++
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,47 / 4,34 5,88 / 4,09
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 256 / 171) 232 / 160)
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++ A+++ / A+++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,31 / 3,26 3,83 / 3,20
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 169 / 127) 150 / 125)
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A++ / A++ A++ / A++
Indoor unit 6kW electric heater WH-ADC0912K6E53
Indoor sound pressure (Heat) dB(A) 33 33
Indoor sound pressure (Cool) dB(A) 33 33
Abmessung (H) mm 2 036 2 036
Abmessung (B) mm 599 599
Abmessung (T) mm 602 602
Nettogewicht kg 119 120
Water pipe connector Inch R11⁄4 R11⁄4
Hocheffizienzpumpe (Drehzahlstufen) Variable Geschwindigkeit Variable Geschwindigkeit
Hocheffizienzpumpe (Leistungsaufnahme max.) W 145 145
Warmwasservolumenstrom (∆T=5 K. 35°C) L/min 25,8 45,9
Speichervolumen L 260 260
Max. Brauchwarmwassertemperatur °C 65 65
Material der Speicherinnenseite Edelstahl Edelstahl
Lastprofil gem. EN16147 XL XL
DHW tank ERP average climate efficiency rating (2) A+ to F A+ A+
DHW tank ERP warm climate efficiency rating (2) A+ to F A+ A+
DHW tank ERP cold climate efficiency rating (2) A+ to F A A
Warmwasserbereitungs-Energieeffizienz ηwh % 123 98
DHW tank ERP average climate COPdHW COPdHW 3,08 2,45
Warmwasserbereitungs-Energieeffizienz η ηwh % 134 123
DHW tank ERP warm climate COPdHW COPdHW 3,35 3,08
Kaltwasserbereitungs-Energieeffizienz η ηwh % 94 80
DHW tank ERP cold climate COPdHW COPdHW 2,35 2,00
Außengerät WH-UXZ09KE5 WH-UXZ16KE8
Outdoor sound power (Heat) (3) dB(A) 65 65
Abmessung (H) mm 1 340 1 340
Outdoor dimension (Width) mm 900 900
Outdoor dimension (Depth) mm 320 320
Nettogewicht kg 88 103
Refrigerant (R290) / CO2 Eq. kg / T 1,60 1,83
Vorgefüllte Kältemittellänge (R32) / CO2 - Äquivalent kg / T 1.080 1.235
Flüssigkeitsleitung Inch (mm) 1/4 (6,35) 1/4 (6,35)
Sauggasleitung Inch (mm) 1/2 (12,70) 1/2 (12,70)
Leitungslänge (min. / max.) m 3 ~ 30 3 ~ 30
Höhenunterschied IG/AG m 20 20
Pipe length for additional gas m 10 10
Additional gas amount g/m 30 30
Operation range - Outdoor ambient (Heat) °C -28 ~ +35 -28 ~ +35
Operation range - Outdoor ambient (Cool) °C +10 ~ +43 +10 ~ +43
Wasseraustrittstemperatur (Heizen) °C 20 ~ 60 20 ~ 60
Wasseraustrittstemperatur (Kühlen) °C 5 ~ 20 5 ~ 20
Electrical information WH-ADC0912K6E53 / WH-ADC0912K6E5AN3 WH-ADC16K9E83 / WH-ADC16K9E8AN3
Electric backup heater kW 6,00 9,00
Recommended fuse A 30 / 30 20 / 20
Recommended minimum cable size, supply 1 (5) mm² 3x4,0 5x2,5
Recommended minimum cable size, supply 2 (5) mm² 3x4,0 5x1,5

1) Scale from A+++ to D.

2) Scale from A+ to F.

3) Sound power in accordance to 811/2013, 813/2013 and EN 12102-1:2017 at +7 °C.

4) Operation range down to -25 °C in heating with 3 ~ 40 m pipe length range, operation range down to -15 °C in heating with 3 ~ 50 m pipe length range.

5) Check local regulations.

* EER and COP calculation is based in accordance to EN 14511.

** This product is designed to comply with the European drinking water standard (EU) 2020/2184. The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.