T-CAP All in One 260L DHW tank M Series 1 phase - 3 phase · R290

T-CAP All in One 260L DHW tank M Series 1 phase - 3 phase · R290

Aquarea T‑CAP M Series delivers a revolution in the design, performance, connectivity, and sustainability

The solution is suitable for both new buildings and retrofits, as it offers a sustainable alternative to traditional fossil fuel heating systems and it can be easily integrated with existing water system such as fan coils, floor heating or domestic hot water tanks.

Now available in a larger All in One version, perfect for homes with high DHW demand. Despite the increased capacity, it maintains a compact footprint of just 599 x 602 mm—similar to a standard appliance.

• Up to 75°C water outlet down to -15°C outdoor
• Quiet operation: Only 29dB(A) sound pressure at 5 m*
• Reliable outdoor units with Panasonic compressor, operating down to -28°C outdoor
• T‑CAP technology: Keeping heating capacity down to -15°C at 55ºC water outlet
• Panasonic Comfort Cloud App and Aquarea Service Cloud included
• Hydraulic connection between indoor and outdoor
• Maintenance free Inox stainless 260L tank
• All in One 599 x 602mm footprint reduces required installation space indoors
• U-Vacua™ insulation panel for higher tank efficiency
• Also available with built-in impressed current anode (AN version) for installation in sites with harsh water quality

Further comfort and peace of mind with Aquarea

Technische Daten

Alles anzeigen
T-CAP All in One 260L DHW tank M Series 1 phase - 3 phase · R290 Dreiphasig
9 kW
Speichervolumen L 260
Outdoor dimension (Depth) mm 430
Outdoor dimension (Width) mm 1.200
Kaltwasserbereitungs-Energieeffizienz η ηwh % 95
Warmwasserbereitungs-Energieeffizienz η ηwh % 136
Warmwasserbereitungs-Energieeffizienz ηwh % 125
Lastprofil gem. EN16147 XL
Material der Speicherinnenseite Edelstahl
Max. Brauchwarmwassertemperatur °C 65
Höhenunterschied IG/AG m 10
Warmwasservolumenstrom (∆T=5 K. 35°C) L/min 25,8
Hocheffizienzpumpe (Leistungsaufnahme max.) W 175
Hocheffizienzpumpe (Leistungsaufnahme min.) W 30
Hocheffizienzpumpe (Drehzahlstufen) Variable Geschwindigkeit
Heating cold climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 4,45 / 3,20
Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 175 / 125
Heating warm climate. Energy class (W 35°C / W 55°C) (1) A+++ to D A+++ / A+++
Indoor unit 6kW electric heater
Outdoor sound power (Heat) (2) dB(A) 52
Indoor unit 9kW electric heater WH-ADC0316M9E83
Pipe length range maximum m 30
Pipe length range standard m 5
Water pipe connector (outdoor units) Inch 11⁄4
Water pipe connector (indoor units) Inch 11⁄4
Water pipe connector (shower) Inch 3/4
Water pipe connector (room) Inch 11⁄4
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 6,33 / 4,40
Indoor unit 3kW electric heater
DHW tank ERP cold climate COPdHW COPdHW 2,35
DHW tank ERP warm climate COPdHW COPdHW 3,35
DHW tank ERP average climate COPdHW COPdHW 3,10
Außentemperatur Grenzwerte (min./max.) (Kühlen) °C +10 ~ +43
Außentemperatur Grenzwerte (min./max.) (Heizen) °C -28 ~ +35
Wasseraustrittstemperatur (Kühlen) °C 5 ~20
Wasseraustrittstemperatur (Heizen) °C 25 ~ 75 (4)
COP (A +7°C, W 35°C) 5,23
Nettogewicht kg 105
Abmessung (H) mm 2.036
EER (A 35°C, W 7°C) 3,61
Kühlleistung (A 35°C, W 7°C) kW 9,00
COP (A -7°C, W 35°C) 3,45
Heizleistung (A -7°C, W 35°C) kW 9,00
COP (A +2°C, W 35°C) 3,81
Heizleistung (A +2°C, W 35°C) kW 9,00
Abmessung (H) mm 1.520
Heizleistung (A +7°C, W 35°C) kW 9,00
COP (A +2°C, W 55°C) 2,54
Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C) ηs % 250 / 173
Mittleres Klima. Raumheizungs-Energieeffizienzklasse (W 35°C / W 55°C) (1) A+++ to D A+++ / A++
Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C) SCOP 5,00 / 3,50
Mittleres Klima. Raumheizungs-Energieeffizienz (W 35°C / W 55°C) ηs % 197 / 137
EER (A 35°C, W 18°C) 5,26
Kühlleistung (A 35°C, W 18°C) kW 9,00
COP (A -7°C, W 55°C) 2,35
Heating capacity (A -7°C, W 55°C) kW 9,00
Heizleistung (A +2°C, W 55°C) kW 9,00
COP (A +7°C, W 55°C) 3,24
Heizleistung (A +7°C, W 55°C) kW 9,00
Außengerät WH-WXG09ME8
Abmessung (T) mm 602
Abmessung (B) mm 599
Nettogewicht kg 161
(1) Scale from A+++ to D.
(2) Sound power level in accordance to EN 12102 under conditions of the EN14825 (part load).
(3) WH-WXG models are hermetically sealed.
(4) Above -15 °C outdoor temperature. Between outdoor ambient -15 °C and -25 °C, the water outlet temperature gradually decreases from 75 °C to 55 °C. Below -25 °C outdoor temperature maximum water outlet temperature is 55 °C.
(5) Check local regulations.

* EER and COP calculation is based in accordance to EN 14511.