12.00kW

OCU-KSC120M08

iCOOL OCU-serien för MT-applikationer

Möjligheten att nå ut till en större målgrupp och täcka den marknad för kondensoraggregat (CDU) som CO₂ ännu inte täcker idag.

Specifikationer

Visa alla
iCOOL OCU-serien - MT
12.00 kW
Model OCU-KSC120M08
Compressors En kompressor
Compatible refrigerants R448A, R449A, R134a, R513A
PED CAT II
Application and nominal cooling capacity MT/LT (kW) MT (12,0)
MT (R449A/R448A) - Cooling capacity at .
ET -15°C, AT 32°C (Min - Max) kW 2,4 - 9,8
ET -15°C, AT 38°C (Min - Max) kW 2,1 - 9,0
ET -15°C, AT 43°C (Min - Max) kW 2,0 - 8,5
ET -10°C, AT 32°C (Min - Max) kW 3,0 - 11,9
ET -10°C, AT 38°C (Min - Max) kW 2,7 - 10,8
ET -10°C, AT 43°C (Min - Max) kW 2,5 - 10,3
ET -5°C, AT 32°C (Min - Max) kW 3,7 - 14,3
ET -5°C, AT 38°C (Min - Max) kW 3,4 - 13,1
ET -5°C, AT 43°C (Min - Max) kW 3,1 - 12,5
MT (R134a/R513A) - Cooling capacity at .
ET -15°C; AT 32°C (Min - Max) kW 1,6 - 5,5
ET -15°C; AT 38°C (Min - Max) kW 1,5 - 5,1
ET -15°C; AT 43°C (Min - Max) kW 1,4 - 4,8
ET -10°C; AT 32°C (Min - Max) kW 2,1 - 6,8
ET -10°C; AT 38°C (Min - Max) kW 1,9 - 6,3
ET -10°C; AT 43°C (Min - Max) kW 1,8 - 6,0
ET -5°C; AT 32°C (Min - Max) kW 2,6 - 8,3
ET -5°C; AT 38°C (Min - Max) kW 2,4 - 7,8
ET -5°C; AT 43°C (Min - Max) kW 2,2 - 7,3
SEPR cooling at ET -10°C AT 32°C 3,48
Annual electricity consumption at ET -10°C AT 32°C kWh/a 20.141
Nominal operating current at ET -10°C MT / -30°C LT AT 32°C and 230 - 400V 50Hz A 14,8
Maximum operating current (in the most loaded phase at 230 - 400V 50Hz) A 20,5
Maximum power consumption kW 9,3
Dimension (Width) mm 1.420
Dimension (Height) mm 963
Dimension (Depth) mm 439
Net weight kg 175
Sound level at 10m dB(A) 40,0
Oil charge dm³ 2,0 + 0,4
Connections (Suction) Inch (mm) 7/8
Connections (Liquid) Inch (mm) 1/2
Liquid receiver dm³ 10
Length of connection piping m 40
Maximum height distance (Evaporator above) m 12
Maximum height distance (Evaporator below) m 12
Which pipes needs to be insulated (Suction / liquid / both) Suction
Recommended insulation thickness mm 13
Maximum quantity of evaporators connected Qty. 7
Evaporation temperature (Min) °C -15
Evaporation temperature (Max) °C 10
Ambient temperature (Min) °C -20
Ambient temperature (Max) °C 43
Condenser .
Fans x diameter mm 1x710
Air flow (Nominal) m³/h 6.920
Fan static pressure Pa N/A
Fan power supply V / ph / Hz 200 - 277 / 1 / 50
Fan power consumption W 280
Nominal fan amperage A 1,2
Compressor - additional data .
Compressor model C-SBS180H00B
Volumetric flow m³/h 5,8 - 19,2
Rotation range rps 32 - 100
Current (Full load amperage) A 15,8
Current (Peak current limit / Locked rotor amperage) A 40 / —
Oil type FV68S (PVE)
Crankcase heater power consumption W 70
CU power supply .
Voltage V / ph / Hz 3x400 / 50 PE+N (TN-S)
Recommended minimum cable cross-section mm² 5x4,0
Recommended minimum protection C25