PACi NX Serie Standard adaptiv kanalenhet Inverter+ - R32

5.0kW

KIT-50PF3Z5 (S-3650PF3E + U-50PZ3E5)

Designad kanalserie PF3

2 installationsmöjligheter (horisontell/vertikal) med hög ESP 150Pa ger flexibel installation.

* Prestandan för nanoe™ X-luft kan förväntas även i en 10 m lång kanal enligt Panasonics interna undersökning.

Ny anpassningsbar enhet i kanalutförande: PF3

Nästa generations kommersiella luftkonditioneringsaggregat är här

Naturlig balans inomhus

Specifikationer

Visa alla
PACi NX Serie Standard adaptiv kanalenhet Inverter+ - R32
5.0 kW
Kit KIT-50PF3Z5
Remote controller CZ-RTC5B
Cooling capacity (Nominal) kW 5,0
Cooling capacity (Min) kW 1,5
Cooling capacity (Max) kW 5,3
EER (Nominal) (1) W/W 2,78
SEER/ηsc (2) % 6,5 A++
Pdesign (cooling) kW 5,0
Input power cooling (Nominal) kW 1,8
Annual energy consumption cooling (3) kWh/a 267
Heating capacity (Nominal) kW 5,0
Heating capacity (Min) kW 1,5
Heating capacity (Max) kW 5,9
COP (Nominal) (1) W/W 3,62
SCOP/ηsc (2) % 4,0 A+
Pdesign at -10°C kW 3,8
Input power heating (Nominal) kW 1,38
Annual energy consumption heating (3) kWh/a 1.303
Indoor unit S-3650PF3E
External static pressure (Nominal) (4) Pa 30
External static pressure (Min) (4) Pa 10
External static pressure (Max) (4) Pa 150
Moisture removal volume L/h 16,0
Indoor air flow (Hi) m³/min 15,0
Indoor air flow (Med) m³/min 12,0
Indoor air flow (Lo) m³/min 1,9
Indoor sound pressure (Hi) (5) dB(A) 34
Indoor sound pressure (Med) (5) dB(A) 30
Indoor sound pressure (Lo) (5) dB(A) 25
Indoor sound power (Hi) dB(A) 57
Indoor sound power (Med) dB(A) 53
Indoor sound power (Lo) dB(A) 48
Indoor dimension (Height) mm 250
Indoor dimension (Width) mm 800
Indoor dimension (Depth) mm 730
Indoor net weight kg 25
nanoe X Generator Mark 2
Outdoor unit U-50PZ3E5
Outdoor power source V 220 - 230 - 240
Current in cooling (1p 220V / 3p 380) A 8,35
Current in cooling (1p 230V / 3p 400) A 8,00
Current in cooling (1p 240V / 3p 415) A 7,65
Current in heating (1p 220V / 3p 380) A 6,45
Current in heating (1p 230V / 3p 400) A 6,20
Current in heating (1p 240V / 3p 415) A 5,95
Outdoor air flow (Cool) m³/min 32,7
Outdoor air flow (Heat) m³/min 31,9
Outdoor sound pressure (Cool -Hi) dB(A) 46
Outdoor sound pressure (Heat -Hi) dB(A) 46
Outdoor sound power (Cool -Hi) dB(A) 64
Outdoor sound power (Heat -Hi) dB(A) 64
Outdoor dimension (Height) mm 619
Outdoor dimension (Width) mm 824
Outdoor dimension (Depth) mm 299
Outdoor net weight kg 35
Pipe diameter (Liquid) Inch (mm) 1/4 (Ø6,35)
Pipe diameter (Gas) Inch (mm) 1/2 (Ø12,7)
Pipe length range m 3 - 20
Elevation difference (in/out) (8) m 15 / 15 (9)
Pipe length for additional gas m 7,5
Additional gas amount g/m 15
Refrigerant (R32) / CO2 Eq. kg / T 1,14 / 0,77
Operating range (Cool - Min) °C -10
Operating range (Cool - Max) °C +43
Operating range (Heat - Min) °C -15
Operating range (Heat - Max) °C +24

1) EER- och COP-beräkningen baseras i enlighet med EN14511.
2) För modeller under 12 kW beräknas SEER och SCOP baserat på värdena i EU/626/2011. För modeller över 12 kW beräknas ηsc / ηsh-värdena baserat på EN 14825.
3) Fabriksinställning.
4) Medium externt statiskt tryck inställt från fabrik.
5) Enheternas ljudtryck visar det värde som uppmätts i positionen 1,5 m under enheten. Ljudtrycket mäts i enlighet med Eurovent 6/C/006-97-specifikationen.
6) Anslut vätskekopplingsröret (Ø6,35-Ø9,52) till vätskeslangsidan på inomhusenheten.
7) Anslut gasröret (Ø12,70-Ø15,88) till inomhusenheten på gasslangsidan.
8) Vid installation av utomhusenheten på en högre position än inomhusenheten.
9) Utomhusenheten placerad lägre / utomhusenheten placerad högre.
* Rekommenderad säkring för inomhusenheten 3A.
** Ovanstående värden gäller vid standardinstallation (horisontell installation i takbjälklaget, luftintag på baksidan) och nanoe™ X OFF.